This paper presents a model based procedure for in situ error compensation of spatially distributed magnetic sensors. The proposed approach is numerically validated on RFX-mod, a magnetically confined plasma experiment presently being upgraded with a new magnetic diagnostic system and a state-of-the-art real time control system. The numerical simulations are performed with the CAFE code; synthetic measurements are used to assess the reliability of the proposed method.
Model Based Procedure for In Situ Error Compensation of Spatially Distributed Magnetic Sensors
Marconato N.; Bettini P.; Alotto P.; Cavazzana R.; Marrelli L.; Torchio R.; Voltolina D.
ID | 458383 |
---|---|
DOI | 10.1109/CEFC46938.2020.9451510 |
PRODUCT TYPE | Conference Proceeding |
LAST UPDATE | 2022-02-20T15:27:59Z |